  • 分子泵.jpg

High-Vacuum Tube Sintering Furnace (Molecular Pump)

This high-vacuum tubular sintering furnace (with a molecular pump) is composed of the tubular electric furnace ZHK-G15123K-610 and the high-vacuum molecular pump control system FJ600-Z. (The molecular pump control system is used in our company’s vacuum/atmosphere tubular electric furnaces and vacuum/atmosphere box-type electric furnaces, among other equipment.)

Contact phone number:

  • Product Description
  • Application areas:
    It is primarily used in industries such as rare-earth production, electronic lighting, crystal annealing, bioceramics, electronic ceramics, special alloys, magnetic materials, precision casting, and metal heat treatment for applications including vacuum sintering, atmosphere-protected sintering, vacuum coating, CVD experiments, and material composition analysis.

    15122725930  

     
     

    I. Operational Convenience;

    1. The gas pipeline connection adopts a quick-connect flange design.

    2. Simplifies the material handling process: a single clamp is sufficient to complete the pneumatic connection, making operation convenient.

    3. The complex flange installation process has been eliminated, thereby reducing the likelihood of furnace tube damage during installation.

    II. Structural Practicality;

    1. The heating furnace chamber consists of upper and lower sections; the upper section can be tilted backward as a whole by 110°, facilitating the loading, unloading, and observation of experimental materials. The furnace chamber is made of high-quality polycrystalline molybdenum. Made by fiber vacuum adsorption, it achieves 50% energy savings and ensures uniform temperature distribution. The electric heating element is constructed from high-resistance, high-quality alloy wire 0Cr27Al7Mo2.

    2. The sealing flange employs a double-ring sealing technology, effectively enhancing the gas tightness at both ends of the furnace tube. The gas supply line features fine-adjustable inlet and outlet flow control.

    3. The air-path brackets at both ends support the air-path assembly, effectively eliminating internal stresses within the assembly and thereby preventing furnace-tube damage caused by such stresses.

    4. Advanced air insulation technology, combined with thermal sensing, automatically activates the exhaust fan when the furnace surface temperature rises to 50°C, rapidly cooling the furnace surface.

    III. Safety of Use;

    1. The furnace chamber is equipped with an automatic power-off function that deactivates the power supply when the furnace door is opened.

    2. Over-temperature protection: When the temperature exceeds the set limit, the power is automatically cut off and an alarm is triggered.

    3. Leakage protection function: the power supply is automatically cut off when a leakage current is detected in the furnace body. These features ensure safe operation.

    IV. Intelligent Control;

    1. The electric furnace temperature control system employs artificial intelligence-based regulation technology, featuring PID control, fuzzy control, and self-tuning capabilities, and allows for the programming of various heating and cooling profiles.

    2. The domestically produced programmable temperature control system allows editing of up to 50 temperature-control programs, while the imported programmable temperature control system allows editing of up to 40 temperature-control programs.

    3. The electric furnace is equipped with an RS-485 conversion interface and can be optionally fitted with specialized software to enable connectivity with a computer. This allows for remote control, real-time monitoring, and historical data recording of a single furnace or up to 200 furnaces. Functions such as report generation.

    V. Peripheral Expandability;

    1. Vacuum control system. Various vacuum control systems enable experiments to be conducted on samples under low, medium, and high vacuum conditions.

    2. Gas flow control system. The inlet gas flow is regulated using a float-type or mass flow controller to meet the experimental requirements under various reaction or protective atmospheres.

    VI. Design Uniqueness;

    This equipment is an independently developed product, featuring multiple proprietary design solutions and engineering drawings. It boasts an aesthetically pleasing appearance, a well-structured design, and user-friendly operation.

    Optional: color touchscreen; The display includes an instrument panel, light-bar graph, real-time curve, historical curve, data report, alarm report, and more, with fully Chinese-language touch-screen operation for ease of use.

    Product Specifications:

     

    1200℃ Vacuum-Atmosphere Tube Furnace with a Single Temperature Zone
    Original product model SK-G05123K SK-G06123K SK-G08123K SK-G10123K SK-G08123K-610 SK-G10123K-610 SK-G12123K-610 SK-G15123K-610
    Current product model ZHK-G05123K ZHK-G06123K ZHK-G08123K ZHK-G10123K ZHK-G08123K-610 ZHK-G10123K-610 ZHK-G12123K-610 ZHK-G15123K-610
    Temperature zone Single temperature zone
    Rated temperature 1200℃
    Heating zone length 420mm 600mm
    Constant-temperature zone length 210mm 300mm
    Quartz tube dimensions in mm Φ50/44×1000 Φ60/52×1000 Φ80/72×1000 Φ100/92×1000 Φ80/72×1200 Φ100/90×1400 Φ120/110×1400 Φ150/140×1400
    Rated power 3KW 4.8KW 6KW
    Rated voltage 220V 380V (single-phase)
    Furnace body dimensions mm 360×580×565 410×770×605 480×770×675
    Weight 75Kg 80Kg 85Kg
    Flange structure Double-ring sealed clamp quick connector Multi-ring seal bolt tightening
    Control accuracy ±1℃
    Temperature control The domestically produced programmable temperature control system allows editing of up to 50 temperature-programming segments. The imported programmable temperature control system allows editing of up to 40 temperature-programming segments (optional).
    Furnace tube material Quartz tube
    Operating temperature ≤1100℃
    Heating element High-resistance electric heating alloy wire
    0Cr27A17Mo2
    (Suggestion) Configure the heating and cooling rates for the furnace tubes. 0°C–1000°C ≤ 10°C/min; 1000°C–1200°C ≤ 5°C/min
    Standard Configuration One complete gas pipeline assembly (including a vacuum pressure gauge), one quartz tube, two quartz plugs, one quartz boat, one hook, and one pair of high-temperature gloves.

     

    1200℃ Vacuum-Atmosphere Tube Furnace with Dual Temperature Zones
    Original product model SK-G05123K-2-420 SK-G06123K-2-420 SK-G08123K-2-420 SK-G08123K-2-610 SK-G10123K-2-610 SK-G12123K-2-610 SK-G15123K-2-610
    Current product model SK-G05123K-2-420 SK-G06123K-2-420 SK-G08123K-2-420 SK-G08123K-2-610 SK-G10123K-2-610 SK-G12123K-2-610 SK-G15123K-2-610
    Temperature zone Dual-temperature zone
    Rated temperature 1200℃
    Heating zone length 420mm 600mm 600mm
    Constant-temperature zone length 280mm 390mm 390mm
    Quartz tube dimensions in mm Φ50/44×1000 Φ60/52×1000 Φ80/72×1000 Φ80/72×1200 Φ100/90×1400 Φ120/110×1400 Φ150/140×1400
    Rated power 3.2KW 4.8KW 6KW
    Rated voltage 220V 380V (three-phase)
    Furnace body dimensions mm 360×580×565 410×770×605 480×770×675
    Weight 75Kg 80Kg 85Kg
    Flange structure Double-ring sealed clamp quick connector Multi-ring seal bolt tightening
    Control accuracy ±1℃
    Temperature control The domestically produced programmable temperature control system allows editing of up to 50 temperature-programming segments. The imported programmable temperature control system allows editing of up to 40 temperature-programming segments (optional).
    Furnace tube material Quartz tube
    Operating temperature ≤1100℃
    Heating element High-resistance electric heating alloy wire
    0Cr27A17Mo2
    (Suggestion) Configure the heating and cooling rates for the furnace tubes. 0°C–1000°C ≤ 10°C/min; 1000°C–1200°C ≤ 5°C/min
    Standard Configuration One complete gas pipeline assembly (including a vacuum pressure gauge), one quartz tube, two quartz plugs, one quartz boat, one hook, and one pair of high-temperature gloves.

     

    1200℃ Vacuum-Atmosphere Tube Furnace with Three Temperature Zones
    Original product model SK-G05123K-3-655 SK-G06123K-3-655 SK-G08123K-3-655 SK-G08123K-3-940 SK-G10123K-3-940 SK-G12123K-3-940 SK-G15123K-3-940
    Current product model ZHK-G05123K-3-655 ZHK-G06123K-3-655 ZHK-G08123K-3-655 ZHK-G08123K-3-940 ZHK-G10123K-3-940 ZHK-G12123K-3-940 ZHK-G15123K-3-940
    Temperature zone Three-temperature zone
    Rated temperature 1200℃
    Heating zone length 655mm 940mm
    Constant-temperature zone length 500mm 700mm
    Quartz tube dimensions in mm Φ50/42×1200 Φ60/52×1200 Φ80/72×1200 Φ80/72×1600 Φ100/90×1600 Φ120/110×1600 Φ150/140×1600
    Rated power 4.8KW 7.2KW 9KW
    Rated voltage 380V (three-phase)
    Furnace body dimensions mm 360×815×555 410×1100×605 480×1100×675
    Weight 95Kg 115Kg 125Kg 125Kg
    Flange structure Double-ring sealed clamp quick connector Multi-ring seal bolt tightening
    Temperature control The domestically produced programmable temperature control system allows editing of up to 50 temperature-programming segments. The imported programmable temperature control system allows editing of up to 40 temperature-programming segments (optional).
    Control accuracy ±1℃
    Furnace tube material Quartz tube
    Operating temperature ≤1100℃
    Heating element High-Resistance Electric Heating Alloy Wire 0Cr27A17Mo2
    (Suggestion) Configure the heating and cooling rates for the furnace tubes. 0℃–1000℃ ≤ 10℃/min; 1000℃–1200℃ ≤ 5℃/min;
    Standard Configuration One complete gas pipeline assembly (including a vacuum pressure gauge), one quartz tube, two quartz plugs, one quartz boat, one hook, and one pair of high-temperature gloves.

     

    1200℃ Vacuum-Atmosphere Tube Furnace with Five Temperature Zones
    Original product model SK-G05123K-5-875 SK-G06123K-5-875 SK-G08123K-5-875 SK-G10123K-5-900 SK-G12123K-5-900 SK-G15123K-5-940
    Current product model ZHK-G05123K-5-875 ZHK-G06123K-5-875 ZHK-G08123K-5-875 ZHK-G10123K-5-900 ZHK-G12123K-5-900 ZHK-G15123K-5-940
    Temperature zone Five Temperature Zones
    Rated temperature 1200℃
    Heating zone length 875mm 920mm 940mm
    Constant-temperature zone length 770mm 800mm 800mm
    Quartz tube dimensions in mm Φ50/42×1400 Φ60/52×1400 Φ80/72×1400 Φ100/90×1600 Φ120/110×1600 Φ150/140×1600
    Rated power 6KW 8.5KW
    Rated voltage 380V (three-phase)
    Furnace body dimensions mm 360×1035×555 410×1060×605 480×1100×675
    Weight 115Kg 125Kg 145Kg 145Kg
    Flange structure Double-ring sealed clamp quick connector Multi-ring seal bolt tightening
    Temperature control The domestically produced programmable temperature control system allows editing of up to 50 temperature-programming segments. The imported programmable temperature control system allows editing of up to 40 temperature-programming segments (optional).
    Control accuracy ±1℃
    Furnace tube material Quartz tube
    Operating temperature ≤1100℃
    Heating element High-Resistance Electric Heating Alloy Wire 0Cr27A17Mo2
    (Suggestion) Configure the heating and cooling rates for the furnace tubes. 0℃–1000℃ ≤ 10℃/min; 1000℃–1200℃ ≤ 5℃/min;
    Standard Configuration One complete gas pipeline assembly (including a vacuum pressure gauge), one quartz tube, two quartz plugs, one quartz boat, one hook, and one pair of high-temperature gloves.

     

     


    Product Application: This product series is used in our company’s vacuum/atmosphere tube furnaces and vacuum/atmosphere box furnaces, among other equipment. It is a complete vacuum control system that integrates vacuum pumping, vacuum measurement, and automatic control for both the furnace tubes and the furnace chambers. The equipment provides users with an experimental environment in which the vacuum level can be precisely controlled.

    Product Specifications:

    Product Name Molecular Pump Unit  
    Product Model FJ-110-25 FJ-600-25 FJ-600-40 FJ-600-Z FJ-1200-Z FJ-1600-Z
    Product Name Unit 110
    (Bellows 25 Connection Type)
    Unit 600-25
    (Bellows 25 Connection Type)
    600-40 unit
    (Bellows 40 connection type)
    Unit 600
    (Direct-connection type)
    Unit 1200
    (Direct-connection type)
    Unit 1600
    (Direct-connection type)
    Vacuum range of use 1 times 10 -1 Pa-1×10 -3 Pa 5 times 10 -1 Pa-5×10 -3 Pa 1 times 10 -1 Pa-1×10 -3 Pa
    Vacuum gauge tube Resistance gauge, ionization gauge
    Vacuum gauge channel Single channel
    Control Method Manual control
    Operating voltage AC 220V ±5% 50Hz
    Vacuum Pump Unit Parameters Two-stage rotary vane vacuum pump Pumping speed: 4 L/s; Ultimate vacuum: 3 × 10 -1 Pa Pumping speed: 8 L/s; Ultimate vacuum: 3 × 10 -1 Pa Pumping speed: 8 L/s; Ultimate vacuum: 3 × 10 -1 Pa Pumping speed: 8 L/s; Ultimate vacuum: 3 × 10 -1 Pa Pumping speed: 16 L/s; Ultimate vacuum: 3×10 -1 Pa Pumping speed: 25 L/s; Ultimate vacuum: 3 × 10 -1 Pa
    Vacuum Generation Equipment Interface 110 L/s, ultimate vacuum degree 6×10 -6 Pa Interface 600 L/s, ultimate vacuum level 5×10 -6 Pa Interface 600 L/s, ultimate vacuum level 5×10 -6 Pa Interface 600 L/s, ultimate vacuum level 5×10 -6 Pa Interface 1200 L/s, ultimate vacuum level 5×10 -6 Pa Interface 1600 L/s, ultimate vacuum level 5×10 -6 Pa
    External dimensions mm
    Weight (kg)
    Add water cooling? Add water cooling Add water cooling